Session Aims & Highlights (2026-11-01)

Main aims

  1. Telescope Pointing.  Resync telescope pointing and perform a short mapping job
     This follows the accidental loss of telescope pointing in the S1469 session and the inabilty to accurrately resync the
     telescope before sky clouded over, and the lack of opportunity in the S1470A session. Coming into the S1470
     session it is believed that scope's pointing error is around 3.7 arc min or less,
  2. AstroMain. Check AstroMain's new CameraSupervisor for any issues or problems. 
    This is new code to perform Camera Repair, either Lite Repair that toggles the USB Port to the SBIG Camera or
    an Aggressive repair that includes stopping CCDSoft, toggle the power to the SBIG Camera and restarting
    CCDSoft again and connecting to the Camera.
  3. Targets.  Acquire images of a selection of variable stars, nearby stars, comets & deep sky targets as allowed by sky conditions.

 Equipment & Software

Highlights

Notes

Summary Plots & Logs

Observing Plan
Image
  
Observing Result
Image
   
Image
 
Dome & Scope Slewing Performance
Image
  
Slew/Centering Performance
Image
  
Sky Conditions (Locate Frames)
Image
  
  Image
 
Session Event Log
Time     Event Detail
21:09:04 Session Created Session Created (Live, 2026-11-01 S01470)
21:09:59   Scope Switched On Telescope Power has been switched on via UPB Switch
21:11:59   Services Started Observatory Services started
21:13:53   Telescope Connected Telescope connected (TheSky6)
21:16:20   Camera1 Connected SBIG Camera connected (Set point -20°C)
21:17:22       Dome Unparked Dome unparked
21:18:15   Dome Opened Dome opened (Opening time 47s, Zigbee 41s)
22:01:21   Automapping Started Automapping started (12 points planned)
22:11:38   Critical Cloud Alert Critical Cloud Alert (Obs.Manager will close the Dome)
22:12:28   Automapping Aborted Automapping aborted (3 points mapped out of 12 points)
22:12:31   Dome Closed Dome closed (Closing time 50s, Zigbee 43s)
22:40:27   Dome Opened Dome opened (Opening time 45s, Zigbee 41s)
22:52:38   Camera1 Connected SBIG Camera connected (Set point -20°C)
22:53:07   Automapping Started Automapping started (12 points planned)
23:08:42   Critical Cloud Alert Critical Cloud Alert (Obs.Manager will close the Dome)
23:09:31   Dome Closed Dome closed (Closing time 49s, Zigbee 43s)
23:11:30   Automapping Aborted Automapping aborted (3 points mapped out of 12 points)
23:15:15   Telescope Parked Telescope parked (parking time 41s total)
23:15:39   Telescope State Handbox reads 'Scope parked Turn scope off.'
23:16:42   Telescope Switched Off Telescope Power has been switched off via UPB Switch.
00:15:45 Session Monitoring AutoStart monitoring for Live Session opportunity between 00:15 & 05:24
00:15:47 Observatory (AutoStart) Observatory placed in Auto-Start Mode
00:15:50   AutoStart Delayed Session delayed due to cloud
00:26:16 Session AutoStarting Session autostarting (00:26)
00:26:23 Session Resumed Session Resumed (Live, 2026-11-01 S01470)
00:26:40   Scope Switched On Telescope Power has been switched on via UPB Switch
00:28:33   Services Started Observatory Services started
00:28:45 Observatory (Auto) Observatory placed in Fully-Automated Mode
00:28:47 Session Pending Session pending (2026-11-01)
00:28:49 Session Initiating Session initiating (2026-11-01)
00:29:03   Camera1 Connected SBIG Camera connected (Set point -20°C)
00:29:08   Plan Requested Observing Plan requested from AstroPlan (1.47.5)
00:33:39   Plan Loaded Observing Plan loaded to queue (PlanID: 1271)
00:33:55   Telescope Connected Telescope connected (TheSky6)
00:34:38 Session Equilibration Session ready to Open Dome
00:35:24   Dome Opened Dome opened (Opening time 45s, Zigbee 41s)
00:35:25 Session Running Session running
00:35:28   Queue Started Observing Queue started (19 targets selected)
00:35:37     Target Started (NrZen) Target started (Focus Field 3, HIP 14181)
00:41:26       Focusing Started-Foc1 Foc1 Focusing Started (TCF-S)
00:46:42       Focusing Completed Foc1 AutoFocus Completed (Profile No 1, wide)
00:49:01       Focusing Failed Foc1 focusing failed (failed QC check - Range)
00:49:32       Focusing Started-Foc2 Foc2 Focusing Started (Secondary Scope, using ShCap)
00:52:29       Focusing Completed Foc2 AutoFocus Completed (Profile No 2, wide)
00:55:07       Focusing Completed Foc2 AutoFocus Completed (Profile No 2)
00:55:42     Target Completed (NrZen) Target completed (Focus Field 3, HIP 14181)
00:55:47     Target Started (1/19) Target started (1/19, UGC 242 w/SN2026yum)
01:05:22       Focusing Started-Foc1 Foc1 Focusing Started (TCF-S)
01:08:40       Focusing Completed Foc1 AutoFocus Completed (Profile No 3, wide)
01:10:38       Focusing Failed Foc1 focusing failed (failed QC check - Quadratic)
01:10:41     Target Failed (1/19) Target failed due to exceeded time slot (1/19, UGC 242 w/SN2026yum)
01:10:44     Target Started (2/19) Target started (2/19, AT2026iul (CV))
01:27:39     Target Failed (2/19) Target failed due to exceeded time slot (2/19, AT2026iul (CV))
01:27:44     Target Started (3/19) Target started (3/19, GCVS HH And)
01:28:06       CCDSoft Restarting CCDSoft being restarted (attempt to fix Camera Exception)
01:28:09       SBIG USB Reset SBIG USB being toggled off/on
01:28:23       Camera1 Connected SBIG Camera connected (Set point -20°C)
01:29:36       SBIG Camera Take Image failed (Command timed-out)
01:29:38       Camera Issue Take Image failed (Frozen CcdCamera)
01:30:33       SBIG Camera Reset SBIG Camera being power-cycled
01:31:36       CCDSoft Issue CCDSoft has encountered an image save issue [0000]
01:31:38       CCDSoft Restarting CCDSoft being restarted (undefined)
01:31:41       SBIG USB Reset SBIG USB being toggled off/on
01:32:09       Camera1 Connected SBIG Camera connected (Set point -20°C)
01:32:12       Camera1 Connected SBIG Camera connected (Set point -20°C)
01:33:02 User Intervention User Intervention to abort job queue & switch back to Manual Mode
01:33:06     Target Failed (3/19) Target failed due to aborted (3/19, GCVS HH And)
01:33:08   Queue Aborted Job Queue aborted
01:33:10 Observatory (Manual) Observatory placed in Manual Mode
01:33:57     Target Started (NrZen) Target started (Focus Field 4, HIP 18637)
01:35:37       Focusing Started-Foc1 Foc1 Focusing Started (TCF-S)
01:36:38         SBIG Camera Take Image failed (Command timed-out)
01:36:40         CCDSoft Restarting CCDSoft being restarted (attempt to fix unsaved file issue)
01:36:45         SBIG Camera Reset SBIG Camera being power-cycled
01:37:46         SBIG Camera Reset SBIG Camera being power-cycled
01:39:19         Camera1 Connected SBIG Camera connected (Set point -20°C)
01:40:17       Focusing Aborted Foc1 Focusing Aborted
01:40:20     Target Aborted (NrZen) Target aborted (Focus Field 4, HIP 18637) due to User Intervention
01:40:56   Services Stopped Observatory Services stopped
01:43:07 Session Resumed Session Resumed (Live, 2026-11-01 S01470)
01:43:09 Program Opened Program Opened (AstroMain 3.84.21)
01:43:19   Obs.Overseer Started Obs.Overseer started
01:45:57   Obs.Manager Started Obs.Manager started
01:45:59   Services Started Observatory Services started
01:46:48   Telescope Connected Telescope connected (TheSky6)
01:51:21   CCDSoft Restarting CCDSoft being restarted (attempt to fix Camera Exception)
01:51:24   SBIG USB Reset SBIG USB being toggled off/on
01:52:58   SBIG Camera Take Image failed (Command timed-out)
01:53:00   CCDSoft Restarting CCDSoft being restarted (attempt to fix Camera Exception)
01:53:05   SBIG Camera Reset SBIG Camera being power-cycled
01:57:00   Camera1 Connected SBIG Camera connected (Set point -20°C)
01:58:08   CCDSoft Restarting CCDSoft being restarted (attempt to fix Camera Exception)
01:58:11   SBIG USB Reset SBIG USB being toggled off/on
01:58:25   CCDSoft Restarting CCDSoft being restarted (attempt to fix Camera Exception)
01:58:31   SBIG Camera Reset SBIG Camera being power-cycled
02:02:56   Camera1 Connected SBIG Camera connected (Set point -20°C)
02:05:55   Camera1 Connected SBIG Camera connected (Set point -20°C)
02:06:25 Session Closing Session closing
02:07:15   Dome Closed Dome closed (Closing time 48s, Zigbee 44s)
02:08:28   Dome Parked Dome parked (parking time 65s), Az: 90.0 deg
02:09:31   Telescope Parked Telescope parked (parking time 47s total)
02:09:55   Telescope State Handbox reads 'Scope parked Turn scope off.'
02:10:52   Telescope Switched Off Telescope Power has been switched off via UPB Switch.
02:11:12   Services Stopped Night Services stopped
02:11:15 Session Finishing Session Finishing started (Create Fits Summary, Transfer Files)
02:11:32     Dome (Find Park) Find Park started (Search Az 88.0 to 92.0°, Step 0.2°, Narrow)
02:12:21     Dome Find Park found (Best Park Az 90.2°)
02:12:27     Dome Dome has been synced at park position (Az 90.0°, Adjustment: -0.2°)
02:12:29   Dome Parked Dome parked
02:14:10   Dome Charging Dome is parked and re-charging Ok (18mA)
02:14:12 Session Finished Session Finished
 
Session Alerts & Alarms
Time     Type       Name Detail
01:29:36 Red Alert SBIG Camera Alert Take Image failed (Command timed-out)
01:29:38 Red Alert Camera Issue Take Image failed (Frozen CcdCamera)
01:31:36 Red Alert CCDSoft Image file [0000] hasn't been saved to disk, possible CCDSoft issue
01:32:57 Green Clear CCDSoft Image file has been saved to disk following CCDSoft Restart
01:36:38 Red Alert SBIG Camera Alert Take Image failed (Command timed-out)
01:40:17 Yellow Alert Focusing LX200 focusing failed (Autofocus Aborted)
01:52:58 Red Alert SBIG Camera Alert Take Image failed (Command timed-out)
02:14:10 Green Clear Dome Charging Dome is parked and re-charging Ok (18mA)
 

Back to Top


Operational Issues (2026-11-01 S1470B)

[ Prev | Next ]

Critical Issues

Major Issues

Minor Issues

Small Defects

Continuous Improvement

[ Prev | Next ]

Back to Top Issue,  Back to Top


Fig 1. Bad Focus Profile created during Near Zenith Focusing of LX200 Telescope

Bad Focus Profile created during Near Zenith Focusing (wide) due to a failure to acquire fresh focus frames and the reuse of stale focus frame image (a CcdSoft/Camera issue).  The Best Focus position was wrongly identifed as a consequence on lead to an invalid Focus Offset being saved and used leading to out-of-focus images seen.

Here is Focus Profile 1 (wide search range) :

Image

The issue with constant resuse of stale image persisted through regular Focus Profiling and also into Target 1/1
This can be seen in Focus Profile 1 (narrow search range) below where FWHM, HFD and Max Pixel show constant values
that are equal to the last valid image in wide search profile. The  Profile and it Best Focus in this case was rejected 
by QC, but the 'damage' had already been done during the preceeding wide search focus profile.

Image

FIg 2 AstroAllSky/CCDSoft Image Life Cycle

' Declarations:
 Public Camera As Object
 Public Image As Object
 Public Image2 As Object
 Public ImageA As Object

Sub form_load()
   Camera = CreateObject(CCDSoftCamera)
End Sub


AllSkyController. ExecuteNightLoop / ExecuteNightCycle:

Do While sunalt < SU.ImagingStartStopAltitude

  If GetCCDSoftPrivateWorkingMemory() > CriticalCCDSoftWorkingMemory Then  RestartCCDSoft()
 

  ImageReady = False
  If ImageQueued  then
    If Camera.State = cdStateTakePicture Then
      Do Until Camera.State = cdStateNone
        ...
      Loop
      ImageReady = True ' set flag to indicate a picture is ready to be processed.
      ImageQueued = False
    ElseIf Camera.State = cdStateNone Then
        ImageReady = True ' set flag to indicate a picture is ready to be processed.
        ImageQueued = False ' flag that image queue is clearly ready to take a new image
   Else
        ImageReady = True ' set flag to indicate a picture is ready to be processed. End If
   End if
End If

  If Not ImageQueued then
      Camera.ExposureTime = Exp
      Camera.Asynchronous = 1

      Camera.TakeImage()
 End if
  If ImageReady Then  
  ImageA = CreateObject("CCDSoft.image")
  ImageA.AttachToActiveImager()
  FitsFilePath = ImageA.Path
  ImageA.Close
End If

If ImageReady Then
   Image = CreateObject("CCDSoft.image")
   Image.Path = FitsFilePath
    Image.Open
    ...
   Image.Save()
  ...
   ImageNum = GetFullImageNum(Image.Path)
  ...
   Image.Save()
   ...
   DataArray = Image.DataArray

   ' SaveAllSkyImageAsBMP()  :
  
       Image.Path = BaseFolder + "\Latest\Latest.AllSky.bmp"
       Image.SaveAs(1)
       Image.DetachOnClose = False
       Image.Close()

   '
   ' frmImage.ImportFullAllSkyImage()
         bm_ImageFull.Dispose() bm_ImageFull = New Bitmap(SU.BaseFolder + "\Latest\Latest.AllSky.bmp")
    ...   ' work with bmp

    Image.Close()

   ' CreateAllSkyDiffImage() 

     Image = CreateObject("CCDSoft.image")
     Image.Path = IV.FilePath Image.Open()
     Image.Visible = 1
     Image.SetActive()

     Image.Path = SessionFolder + "\_DIFF\" + GetFullImageNum(IV.ImageNum) + ".FIT" '' IV.FileName

     LastDataArray = ImageCache.GetLastImage(LastImageTime, LastImageNum)
     For x = 0 To IV.nX - 1
       For y = 0 To IV.nY - 1
         Delta = DataArray(x, y) - LastDataArray(x, y)
         a = Delta + 10000
         If a > 66535 Then  a = 66535
         If a < 0 Then  a = 0
         DataArray2(x, y) = a
       Next
      Next
      LastDataArray = DataArray
      ImageCache.Store(DataArray, DateTime.Parse(IV.LocalDate + " " + IV.LocalTime), IV.ImageNum)

      Image.DataArray = DataArray2
      Image.Save()

      Image.Path = BaseFolder + "\Latest\Latest.AllSkyDiff.bmp"
      Image.SaveAs(1)
      Image.DetachOnClose = False
      Image.Close()
End if
loop

Sub RestartCCDSoft()
     KillCCDSoft()                                                     '  no Camera.disconnect, no camera disposal
     Camera = CreateObject(CCDSoftCamera)   ' this automatically starts CCDSoft
     Camera.Connect()